Theses

Development of direct measurement techniques for the in-situ internal alignment of accelerating structures.

Año

2018

Autor

  Natalia Galindo Muñoz

Director(es)

  Vicente E. Boria Esbert

Abstract

In the next generation of linear particle accelerators, challenging alignment tolerances are required in the positioning of the components focusing, accelerating and detecting the beam over the accelerator length in order to achieve the maximum machine performance. In the case of the Compact Linear Collider (CLIC), accelerating structures, beam position monitors and quadrupole magnets need to be aligned in their support with respect to their reference axes with an accuracy of 10 um. To reach such objective, the PACMAN (Particle Accelerator Components Metrology and Alignment to the Nanometer Scale) project strives for the improvement of the current alignment accuracy by developing new methods and tools, whose feasibility should be validated using the major CLIC components. This Ph.D. thesis concerns the investigation, development and implementation of a new non-destructive intracavity technique, referenced here as 'the perturbative method', to determine the electromagnetic axes of accelerating structures by means of a stretched wire, acting as a reference of alignment. Of particular importance is the experimental validation of the method through the 5.5 mm iris-mean aperture CLIC prototype known as TD24, with complex mechanical features and difficult accessibility, in a dedicated test bench. In the first chapter of this thesis, the alignment techniques in particle accelerators and the novel proposals to be implemented in the future linear colliders are introduced, and a detailed description of the PACMAN project is provided. The feasibility study of the method, carried out with extensive electromagnetic fields simulations, is described in chapter 2, giving as a result, the knowledge of the theoretical accuracy expected in the measurement of the electromagnetic axes and facilitating the development of a measurement algorithm. The conceptual design, manufacturing and calibration of the automated experimental set-up, integrating the solution developed to measure the electromagnetic axes of the TD24, are covered in chapter 3. The future lines of research and developments of the perturbative method are also explored. In chapter 4, the most significant results obtained from an extensive experimental work are presented, analysed and compared with simulations. The proof-of-principle is completed, the measurement algorithm is optimised and the electromagnetic centre is measured in the TD24 with a precision less than 1 um and an estimated error less than 8.5 um. Finally, in chapter 5, the developments undertaken along this research work are summarised, the innovative achievements accomplished within the PACMAN project are listed and its impact is analysed.

Páginas

147